{"product_id":"shell-water-detector-80-tests-box","title":"SHELL WATER DETECTOR (80 TESTS\/BOX)","description":"\u003cstyle\u003e\n  .row {\n  \/*margin: 1% 0;*\/\n  overflow: hidden;\n}\n.row::after {\n        content: \"\";\n        clear: both;\n        display: table;\n    }\n.row--margins {\n    margin: 1rem 0;\n  }\n.row--margin-top {\n    margin-top: 1rem;\n  }\n.row--margin-bottom {\n    margin-bottom: 1rem;\n  }\n.row--gutters {\n    margin-right: -65px;\n  }\n.row--gutters-medium {\n    margin-right: -40px;\n  }\n.row--gutters-small {\n    margin-right: -10px;\n  }\n.row--gutters \u003e [class*=\"row__col-\"],\n  .row--gutters \u003e div \u003e [class*=\"row__col-\"] {\n    padding-right: 65px;\n  }\n.row--gutters-medium \u003e [class*=\"row__col-\"],\n  .row--gutters-medium \u003e div \u003e [class*=\"row__col-\"] {\n    padding-right: 40px;\n  }\n.row--gutters-small \u003e [class*=\"row__col-\"],\n  .row--gutters-small \u003e div \u003e [class*=\"row__col-\"] {\n    padding-right: 10px;\n  }\n.row--gaps-small \u003e [class*=\"row__col-\"]{\n    padding-top: 1.5rem;\n    padding-bottom: 1.5rem;\n  }\n.row--same-height {\n    display: flex;\n    flex-wrap: wrap;\n  }\n.row--same-height [class*=\"row__col-\"] {\n    overflow: hidden;\n  }\n.row--overflow {\n    overflow: visible;\n  }\n.row--overflow [class*=\"row__col-\"] {\n      overflow: visible;\n    }\n.row--overflow .row__col-static {\n      position: static;\n    }\n.row__col-static {\n    position: static;\n  }\n.row__col-12 {\n    width: 100%;\n  }\n.row__col-11 {\n    width: 91.66%;\n  }\n.row__col-10 {\n    width: 83.33%;\n  }\n.row__col-9 {\n    width: 75%;\n  }\n.row__col-8 {\n    width: 66.66%;\n  }\n.row__col-7 {\n    width: 58.33%;\n  }\n.row__col-6 {\n    width: 50%;\n  }\n.row__col-5 {\n    width: 41.66%;\n  }\n.row__col-4 {\n    width: 33%;\n  }\n.row__col-3-5 {\n    width: 30%;\n  }\n.row__col-3 {\n    width: 25%;\n  }\n.row__col-2-5 {\n    width: 20%;\n  }\n.row__col-2 {\n    width: 16.66%;\n  }\n.row__col-1 {\n    width: 8.33%;\n  }\n.row__block-spacer {\n    height: 100%;\n  }\n.row__block-spacer--grey {\n    background-color: #F4F4F2;\n  }\n[class*=\"row__col-\"] {\n  float: left;\n  min-height: 1px;\n  position: relative;\n}\n@media (max-width: 960px) {\n  .row{\n    margin-right: 0;\n  }\n  [class*=\"row__col-\"] {\n    float: none;\n    width: 100%;\n    padding-right: 0 !important;\n  }\n    }\n  .row img{\n    width:100%;\n  }\n  .swd__step-number\n {\n    display: inline-block;\n    vertical-align: middle;\n    height: 5rem;\n    width: 5rem;\n    line-height: 5rem;\n    background-color: #931b25;\n    color: #ffffff;\n    font-size: 2rem;\n    text-align: center;\n}\n  .swd__step{\n    display: flex;\n    gap: 10px;\n    align-items: center;\n  }\n  .headline{ color: rgba(var(--color-button)); }\n\u003c\/style\u003e\n\n\u003cdiv class=\"shell-water-detector swd\"\u003e\n\t\u003cdiv class=\"row row--same-height row--gutters\"\u003e\n\t\t\u003cdiv class=\"row__col-12\"\u003e\n\t\t\t\u003cdiv class=\"swd__intro-content\"\u003e\n\t\t\t\t\u003ch2 class=\"headline headline--medium headline--blue headline--half-bottom-margin\"\u003eNew, Easier-to-Use Packaging\u003c\/h2\u003e\n\t\t\t\t\u003cp\u003eScrew-top tubes can be difficult to use, especially when wearing gloves.\u003c\/p\u003e\n\t\t\t\t\u003ch3 class=\"headline headline--medium headline--blue headline--thin\"\u003eWe understand the importance of sampling efficiently while wearing the correct personal protective equipment, which is why our new \u003cstrong\u003eShell Water Detector\u003c\/strong\u003e tubes have flip caps.\u003c\/h3\u003e\n\t\t\t\t\u003cp\u003eThese are easy to open and seal with one hand while wearing gloves. We also recommend using reverse-action syringes, which draw samples in when the plunger is pushed – an action that can be performed easily using one hand.\u003c\/p\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__intro-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-testing-fuel_3d025ca5-b8aa-4ebe-8750-23bc853e68c5.jpg?v=1772127135\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__intro-content\"\u003e\n\t\t\t\t\u003ch2 class=\"headline headline--medium headline--blue headline--half-bottom-margin\"\u003eTrusted Worldwide\u003c\/h2\u003e\n\t\t\t\t\u003cp\u003eFor over 50 years, operators across the world have relied on the \u003cstrong\u003eShell Water Detector\u003c\/strong\u003e to check their aviation fuel for suspended water that cannot be detected by visual inspections. The detector capsules are widely used, thanks to their effectiveness and simplicity.\u003c\/p\u003e\n\t\t\t\t\u003cp\u003eImitations are available, but, for quality you can trust, we recommend using the original, internationally recognised, industry standard that is the \u003cstrong\u003eShell Water Detector\u003c\/strong\u003e.\u003c\/p\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__intro-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-check-fuel_deee3914-8a77-4142-b3c2-778456ea311b.jpg?v=1772127136\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__intro-content\"\u003e\n\t\t\t\t\u003ch2 class=\"headline headline--medium headline--blue headline--half-bottom-margin\"\u003eCheck Your Fuel!\u003c\/h2\u003e\n\t\t\t\t\u003cp\u003eLow concentrations of water suspended in fuel cannot be detected by visual inspections. Thankfully, there is an easy-to-use test that you can rely on to verify that your jet fuel meets demanding aviation standards for water content.\u003c\/p\u003e\n\t\t\t\t\u003cp\u003eThe \u003cstrong\u003eShell Water Detector\u003c\/strong\u003e is a long-established and trusted industry-standard test for water in fuel. It is manufactured to Shell’s high quality requirements for reliable testing throughout the fuel supply chain.\u003c\/p\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\n\t\u003cdiv class=\"row\"\u003e\n\t\t\u003cdiv class=\"row__col-12\"\u003e\n\t\t\t\u003cdiv class=\"title-block title-block--grey\"\u003e\n\t\t\t\t\u003ch2 class=\"headline headline--medium\"\u003eWHEN TO USE\u003c\/h2\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\n\t\u003cdiv class=\"row row--same-height row--gutters-small\"\u003e\n\t\t\u003cdiv class=\"row__col-4\"\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-when-to-use-1_38a615c2-c4c9-4559-83db-96cdaee72a8a.jpg?v=1772127138\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-content\"\u003e\n\t\t\t\t\u003cp class=\"text text--small text--half-top-margin\"\u003eEach in-service tank daily\n\t\t\t\u003c\/p\u003e\n\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-4\"\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-when-to-use-2_a4cc7312-1a91-45a7-9c38-6c15caaa39cb.jpg?v=1772127139\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-content\"\u003e\n\t\t\t\t\u003cp class=\"text text--small text--half-top-margin\"\u003eEach filter drain (hydrant filter\/loading filter) daily\n\t\t\t\u003c\/p\u003e\n\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-4\"\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-when-to-use-3_2062936f-6dac-46f9-a9e8-216e5c75716a.jpg?v=1772127141\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-content\"\u003e\n\t\t\t\t\u003cp class=\"text text--small text--half-top-margin\"\u003eEach fueller filter drain daily and as per JIG 1 5.3.1\n\t\t\t\u003c\/p\u003e\n\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-4\"\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-when-to-use-4_b58d8288-75ca-4098-8931-d780480eccd0.jpg?v=1772127143\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-content\"\u003e\n\t\t\t\t\u003cp class=\"text text--small text--half-top-margin\"\u003eEach hydrant dispenser daily and as per JIG 1 5.3.2\n\t\t\t\u003c\/p\u003e\n\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-4\"\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-when-to-use-5_d7c170f9-609b-42ac-8572-b2a0050abdc7.jpg?v=1772127144\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__when-to-use-content\"\u003e\n\t\t\t\t\u003cp class=\"text text--small text--half-top-margin\"\u003eAll fueller and trailer tanks daily and as per JIG 1 5.3.1\n\t\t\t\u003c\/p\u003e\n\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\n\t\u003cdiv class=\"row\"\u003e\n\t\t\u003cdiv class=\"row__col-12\"\u003e\n\t\t\t\u003cdiv class=\"title-block title-block--thin title-block--grey\"\u003e\n\t\t\t\t\u003ch2 class=\"headline headline--medium\"\u003eHOW TO USE\u003c\/h2\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\n\t\u003cdiv class=\"row row--same-height row--gutters swd__steps\"\u003e\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__step\"\u003e\n\t\t\t\t\u003cspan class=\"swd__step-number text--bold\"\u003e1\u003c\/span\u003e\n\t\t\t\t\u003ch3 class=\"swd__step-headline headline headline--no-margins headline--medium headline--blue\"\u003eCheck the Equipment\u003c\/h3\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-how-to-use-1_22765615-df6f-4364-92aa-a674d9b1b4ea.jpg?v=1772127145\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-content\"\u003e\n\t\t\t\t\u003cul\u003e\n\t\t\t\t\t\u003cli\u003eCheck the tube expiry date.\u003c\/li\u003e\n\t\t\t\t\t\u003cli\u003eEnsure that the sample jar is clean and free from water.\u003c\/li\u003e\n\t\t\t\t\t\u003cli\u003eCheck that the 5-ml (0.2-fl-oz) syringe operates freely and that the nozzle is undamaged.\u003c\/li\u003e\n\t\t\t\t\u003c\/ul\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__step\"\u003e\n\t\t\t\t\u003cspan class=\"swd__step-number text--bold\"\u003e2\u003c\/span\u003e\n\t\t\t\t\u003ch3 class=\"swd__step-headline headline headline--no-margins headline--medium headline--blue\"\u003eFit the Capsule\u003c\/h3\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-how-to-use-2_afa6fa56-35ea-437b-9b2c-f36b0f1589e8.jpg?v=1772127147\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-content\"\u003e\n\t\t\t\t\u003cul\u003e\n\t\t\t\t\t\u003cli\u003eRemove a capsule from the tube. Do not touch or allow any moisture onto the yellow paper of the capsule.\u003c\/li\u003e\n\t\t\t\t\t\u003cli\u003eClose the tube to protect the remaining capsules from the ambient humidity.\u003c\/li\u003e\n\t\t\t\t\t\u003cli\u003eCheck that paper is uniformly yellow. If it is not, use another capsule.\u003c\/li\u003e\n\t\t\t\t\t\u003cli\u003eFit the capsule to the syringe with the plunger ready for use.\u003c\/li\u003e\n\t\t\t\t\u003c\/ul\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__step\"\u003e\n\t\t\t\t\u003cspan class=\"swd__step-number text--bold\"\u003e3\u003c\/span\u003e\n\t\t\t\t\u003ch3 class=\"swd__step-headline headline headline--no-margins headline--medium headline--blue\"\u003eDraw a Sample\u003c\/h3\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-how-to-use-3_62ebcb9d-53dd-4287-ac96-0669bc2aabc5.jpg?v=1772127148\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-content\"\u003e\n\t\t\t\t\u003cul\u003e\n\t\t\t\t\t\u003cli\u003eUse the sample from the visual “clear and bright” check you have just completed.\u003c\/li\u003e\n\t\t\t\t\t\u003cli\u003eIf you do not already have the sample, follow the visual inspection procedures (ASTM D4176).\u003c\/li\u003e\n\t\t\t\t\u003c\/ul\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__step\"\u003e\n\t\t\t\t\u003cspan class=\"swd__step-number text--bold\"\u003e4\u003c\/span\u003e\n\t\t\t\t\u003ch3 class=\"swd__step-headline headline headline--no-margins headline--medium headline--blue\"\u003eImmerse the Capsule In the Sample\u003c\/h3\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-how-to-use-4_dfc5e45e-3d19-4258-84ca-fb4f8c051655.jpg?v=1772127150\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-content\"\u003e\n\t\t\t\t\u003cul\u003e\n\t\t\t\t\t\u003cli\u003eEnsure you are using gloves that are impervious to fuel.\u003c\/li\u003e\n\t\t\t\t\t\u003cli\u003eImmerse the capsule and about half the syringe in the sample and stir in a circular motion.\u003c\/li\u003e\n\t\t\t\t\u003c\/ul\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"row row--same-height row--gutters row--margin-top swd__steps\"\u003e\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__step\"\u003e\n\t\t\t\t\u003cspan class=\"swd__step-number text--bold\"\u003e5\u003c\/span\u003e\n\t\t\t\t\u003ch3 class=\"swd__step-headline headline headline--no-margins headline--medium headline--blue\"\u003eExtract the Sample\u003c\/h3\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-how-to-use-5_d56163ed-877c-427f-aca0-b4666662c882.jpg?v=1772127151\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-content\"\u003e\n\t\t\t\t\u003cul\u003e\n\t\t\t\t\t\u003cli\u003eDraw 5 ml of fuel into the syringe.\u003c\/li\u003e\n\t\t\t\t\t\u003cli\u003eMany operators favour a reverse action (single-handed) syringe, which draws a sample when the plunger is pushed, rather than a traditional syringe that needs holding in one hand while the other pulls the plunger.\u003c\/li\u003e\n\t\t\t\t\u003c\/ul\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__step\"\u003e\n\t\t\t\t\u003cspan class=\"swd__step-number text--bold\"\u003e6\u003c\/span\u003e\n\t\t\t\t\u003ch3 class=\"swd__step-headline headline headline--no-margins headline--medium headline--blue\"\u003eWithdraw the Syringe and Examine the Capsule\u003c\/h3\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-how-to-use-6_8b42794b-c372-43fb-aae1-c810fd82e276.jpg?v=1772127153\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-content\"\u003e\n\t\t\t\t\u003cul\u003e\n\t\t\t\t\t\u003cli\u003eWithdraw the syringe from the fuel and examine the capsule immediately for any colour change in the centre-wet area.\u003c\/li\u003e\n\t\t\t\t\u003c\/ul\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__step\"\u003e\n\t\t\t\t\u003cspan class=\"swd__step-number text--bold\"\u003e7\u003c\/span\u003e\n\t\t\t\t\u003ch3 class=\"swd__step-headline headline headline--no-margins headline--medium headline--blue\"\u003eResults\u003c\/h3\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-how-to-use-7_5820031e-2ebd-4bab-bbe0-a59ee83f85be.jpg?v=1772127154\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-content\"\u003e\n\t\t\t\t\u003cp\u003eThe yellow wet area turns yellow–green in the presence of very low concentrations of dispersed water. The change to green becomes progressively more noticeable with increasing water content.\u003c\/p\u003e\n\t\t\t\t\u003ctable class=\"table\"\u003e\n\t\t\t\t\t\u003cthead\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003cth\u003eColor\u003c\/th\u003e\n\t\t\t\t\t\t\t\u003cth\u003eResult\u003c\/th\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\u003c\/thead\u003e\n\t\t\t\t\t\u003ctbody\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003eNo Change\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003eAcceptable\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003eA few green speckles or a slight change in color\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003eTrace\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003eDistinct color change\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003eSuspended Water\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\u003c\/tbody\u003e\n\u003ctbody\u003e\n\t\t\t\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\t\t\t\t\u003cp\u003e\u003cem\u003eIf there is any colour change, test a new sample to ensure that the first capsule was not faulty. If there is still a colour change with the second and a third test sample, water is present in the fuel.\u003c\/em\u003e\u003c\/p\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"row__col-6\"\u003e\n\t\t\t\u003cdiv class=\"swd__step\"\u003e\n\t\t\t\t\u003cspan class=\"swd__step-number text--bold\"\u003e8\u003c\/span\u003e\n\t\t\t\t\u003ch3 class=\"swd__step-headline headline headline--no-margins headline--medium headline--blue\"\u003eAfter Sampling\u003c\/h3\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-image\"\u003e\n\t\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-how-to-use-8_dd063f22-5ce5-4b12-b3c3-3db782a8a044.jpg?v=1772127156\"\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\t\u003cdiv class=\"swd__step-content\"\u003e\n\t\t\t\t\u003cul\u003e\n\t\t\t\t\t\u003cli\u003eDispose of the used capsule safely. It can only be used once. Empty the contents of the syringe back into the sample container and return to the recovery tank. Complete the documentation.\u003c\/li\u003e\n\t\t\t\t\u003c\/ul\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Shell Aviation","offers":[{"title":"Default Title","offer_id":45105318756547,"sku":"SWD\/JM-3764\/AER3019","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1799\/0593\/files\/shell-water-detector-8-tubes-10-pills-tube-case-1.jpg?v=1772127162","url":"https:\/\/www.apsaviation.com\/products\/shell-water-detector-80-tests-box","provider":"APS Aviation","version":"1.0","type":"link"}